概要:www.67jzw.com800/15.8=204ψ=0.174N/Aψ=14.6103/(0.174489)=171.6N/mm2<205N/mm2满足要求组合风荷载时对A杆的验算N=1.2(NGlk+Rgb)+0.851.4Rqb =1.2(3+0.89)+0.851.47.1=13.1kN计算风载标准值Wk=0.7μsμzω0=0.71.771.30.770.6 =0.74kN/m2立杆长细比λ=l0/i=kμh/i=1.1551.501800/15.8=204Mω=(0.851.40.741.41.82)/10=0.057kN·mN/Aψ+Mω/W=13.1103/(0.186489) +0.4103/(5.08103)=144.1N/mm2<205N/mm2连墙件计算:取24m高处,μz=1.6ωk=0.71.60.770.6=0.52kN/m2Nl=1.40.52(61.81.4)=11kNNl=11kN<28=16kN所以要2个扣件才能满足抗滑承载力要求Nl/A=11103/489=22.5N/mm2<205N/mm2满足要求验
脚手架专项施工方案,标签:安全文明施工措施,安全施工,http://www.67jzw.comwww.67jzw.com800/15.8=204
ψ=0.174
N/Aψ=14.6103/(0.174489)=171.6N/mm2<205N/mm2
满足要求
组合风荷载时对A杆的验算
N=1.2(NGlk+Rgb)+0.851.4Rqb
=1.2(3+0.89)+0.851.47.1=13.1kN
计算风载标准值
Wk=0.7μsμzω0=0.71.771.30.770.6
=0.74kN/m2
立杆长细比
λ=l0/i=kμh/i=1.1551.501800/15.8=204
Mω=(0.851.40.741.41.82)/10=0.057kN·m
N/Aψ+Mω/W=13.1103/(0.186489) +0.4103/(5.08103)
=144.1N/mm2<205N/mm2
连墙件计算:取24m高处,μz=1.6
ωk=0.71.60.770.6=0.52kN/m2
Nl=1.40.52(61.81.4)=11kN
Nl=11kN<28=16kN
所以要2个扣件才能满足抗滑承载力要求
Nl/A=11103/489=22.5N/mm2<205N/mm2
满足要求
验算拉杆长细比及稳定:
A=489mm2 i=15.8mm W=5.08103mm3
λ=1.2745/15.8=36.13<[λ]=350
N/Aψ=11103/(0.899489)=25 N/mm2<205 N/mm2 满足要求
(二)悬挑工字钢力学验算
技术保证措施
该脚手架采用企业工法:《高层建筑沿高度分段搭设、拆除工字钢外悬挑工具式www.67jzw.com脚手架施工工法》中设置方式。
搭设前施工班长应熟悉有关图纸及设计变更,搭设时,三人一组,技术员现场指导。
荷载统计:
装修施工按三层操作面考虑:2×3=6KN/m2
脚手板按三层满铺:0.35×3=0.1 KN/m2
钢管立杆承受自重: 0.1248 KN/m
扣件自重: 14.6 N/个
集中力:
F1(内立杆荷载)=Na=14.6KN
F2(外立杆荷载)=Nb=10.5KN
F3(工字钢自重)=205×10-3×1.8=0.37 KN
Mmax=F1×0.7+F2×1.7= 14.6×0.7+10.5×1.7+0.37×0.9=28.4 KN.m
4、选型:截面抵抗矩WX= Mmax/f=28.4×106/215=132.1×103mm3=132.1cm3
选用热轧普通工字钢16号型钢WX= 140.9cm3
截面惯性矩IX=1127 cm4
半截面面积矩SX=80.8 cm3
腹板厚度t=6.0mm
弹性模量E=2.1×104 KN/cm3
5、剪应力计算:
τmax=VSx/Ixt=(F1+F2++F3) /Ixt=(14.6+10.5+0.37)×80.8×106 /1127×6×104=30.4<fv=125N/mm2
满足要求
6、挠度计算:
荷载标准值
F1=Na=14.6KN F2=Nb=10.5KN F3=0.37 KN
W=W1+www.67jzw.comW2+W3=【F1a12(1+a1/L)+ F2a22(1+a2/L)+ F3a32(1+a3/L)】L/3EI
=【14.6×702(1+70/110)+ 10.5×1702(1+170/110)+ 0.37×902(1+90/110)】×110/3×2.1×104×1127=1.4mm<【W】=1800/400=4.5mm
7、Φ18钢筋箍验算:
钢筋受拉力:F4=(14.6×0.7+10.5×1.7+0.37×0.9)/1.1=25.8 KN
Φ18钢筋套箍直径18mm ,I级钢设计强度值为210 kN/mm2
Ntb=3.14×182/4×210=53.4KN
Ntb=53.4>25.8KN(满足要求)
查施工手册,Φ18螺栓的极限承载力Ft=32.08 KN,
Ft=32.08KN>25.8KN(满足要求)
8、压应力验算
1)局部压应力验算 F2=14.6KN
查16号热轧普通工字钢表 r=8.0mm tw=6.00 t=9.9mm a1(钢管管径)=48mm a2(砼受压区)=50mm hy=r+t=8.0+9.9=17.9mm
Lz=a+2hy=48+17.9×2=83.3mm
取集中荷载增大系数φ=1.0
σС=ψF2/(twLz)=1.0×14.6×103/6×83.8=29N/mm2<f=215N/mm2(符合要求)
2)最大压应力验算 Fmax=F1+F2+F3+F4=14.6+10.5+0.37+25.8=51.3KN
hy=r+t=8.0+9.9=17.9mm
上一篇:m7.5水泥砂浆参考配合比